Premium performance
• Premium blankets may reduce heat loss by up to 80% in the perioperative environment.
• No floating
• No disruption of airflow in the surrounding environment
• Active and passive use
The Mistral-Air® Premium Upper Body blanket MA3360 has an insulating top layer and is designed to warm the upper part of your patient in supine position with both arms positioned away from the body and can be used throughout the perioperative pathway.
Prevent unwanted airflow
The Premium Upper Body blanket MA3360 features a U-shaped neck to optimise blanket positioning, adhesive tape to prevent unwanted airflow to the surgical field, integrated tie strips on the sides to help secure the blanket. It also has a clear face shield to form a “tent” of warm air surrounding the head of your ventilated patient.
The strips are located halfway up, to maintain visibility on the lower arm and to observe the IV line.
Blue 2 Body is the norm when using our warming blankets.
Mistral-Air® blankets need to be used with the soft blue material towards the patient’s skin. When used oppositely the treatment will be ineffective. The blue side provides the air distribution towards the patient.
Always unfold and position the blanket with the blue side towards your patient skin.
Use the optional hose clamp
The two air inlets provide more flexibility when positioning the Mistral-Air® warming unit.
To begin warming, first, open the perforated strips of the air inlet and insert the hose end. Insert the hose into the hose connector until the ring is fully plugged in. Secure the hose with the hose clamp, and switch on the Mistral-Air® warming unit. Warming therapy begins at the default temperature setpoint of 38 degrees Celsius.
• Premium blankets may reduce heat loss by up to 80% in the perioperative environment.
• No floating
• No disruption of airflow in the surrounding environment
• Active and passive use
• Non-allergic (non-latex)
• Non-flammable (16 CFR 1610)
• Non-linting (EN 13795)
• Biocompatibility
• Non-toxic ( ISO 10993)
• X-ray translucent
• Non–MRI
• Optimal air distribution
• The warm air of the high-volume Mistral-Air® blower is evenly distributed in the warming blanket due to the aerodynamic attuned design of the Mistral-Air® warming blankets.
Specification | Value |
---|---|
Dimensions | 2010 x 760 mm |
Application | Holding, OK, PACU, ICU |
Position | Supine, Prone, Lateral |
Surgery | Abdominal, hip, leg, gynae |
Quantity box | 40 pc |
Specification | Premium blanket | Plus blanket |
---|---|---|
Reference number | MA3360 | MA2260 |
Hose connectors | 2. | 2. |
Insulating, water repellent top layer | - |